An IPE section table gives dimensions, mass, area, second moment of area and section modulus for each size; IPE 200 is 200 mm high and weighs 22.4 kg/m.
- Published:
- Updated:
- Reading time
- 5 min read

Contents
An IPE beam section table lists, for each size, the cross-section dimensions, mass per metre, area, second moment of area and section modulus. IPE 200, for example, is 200 mm high, weighs 22.4 kg/m and, per Eurocode Applied, has an elastic section modulus of about 194.3 cm³. Dimensions in this series follow EN 10365.
Below is the full table from IPE 80 to IPE 600, with what each column means and where it is used.
What does an IPE section table show?
The number after the name is the section height in millimetres. The IPE beam range in our catalog has 18 sizes in grade S235JR, in 12 m lengths. In Iran this kind of table is known by the German word for steel, Stahl. Our rebar and IPE weight table covers rebar areas and beam weights; this article covers the section itself: flange and web sizes, and the figures that describe how a beam behaves in bending.
- h: overall section height
- b: flange width
- tw: web thickness
- tf: flange thickness
- r: root radius between flange and web
- A: cross-section area
IPE dimensions, area and weight table
Dimensions and weights are from the Ahan Assa catalog; areas are from the Eurocode Applied table.
| Size | h (mm) | b (mm) | tw (mm) | tf (mm) | r (mm) | A (cm²) | Mass (kg/m) | 12 m bar (kg) |
|---|---|---|---|---|---|---|---|---|
| IPE 80 | 80 | 46 | 3.8 | 5.2 | 5 | 7.64 | 6 | 72 |
| IPE 100 | 100 | 55 | 4.1 | 5.7 | 7 | 10.32 | 8.1 | 97.2 |
| IPE 120 | 120 | 64 | 4.4 | 6.3 | 7 | 13.21 | 10.4 | 124.8 |
| IPE 140 | 140 | 73 | 4.7 | 6.9 | 7 | 16.43 | 12.9 | 154.8 |
| IPE 160 | 160 | 82 | 5 | 7.4 | 9 | 20.09 | 15.8 | 189.6 |
| IPE 180 | 180 | 91 | 5.3 | 8 | 9 | 23.95 | 18.8 | 225.6 |
| IPE 200 | 200 | 100 | 5.6 | 8.5 | 12 | 28.48 | 22.4 | 268.8 |
| IPE 220 | 220 | 110 | 5.9 | 9.2 | 12 | 33.37 | 26.2 | 314.4 |
| IPE 240 | 240 | 120 | 6.2 | 9.8 | 15 | 39.12 | 30.7 | 368.4 |
| IPE 270 | 270 | 135 | 6.6 | 10.2 | 15 | 45.95 | 36.1 | 433.2 |
| IPE 300 | 300 | 150 | 7.1 | 10.7 | 15 | 53.81 | 42.2 | 506.4 |
| IPE 330 | 330 | 160 | 7.5 | 11.5 | 18 | 62.61 | 49.1 | 589.2 |
| IPE 360 | 360 | 170 | 8 | 12.7 | 18 | 72.73 | 57.1 | 685.2 |
| IPE 400 | 400 | 180 | 8.6 | 13.5 | 21 | 84.46 | 66.3 | 795.6 |
| IPE 450 | 450 | 190 | 9.4 | 14.6 | 21 | 98.82 | 77.6 | 931.2 |
| IPE 500 | 500 | 200 | 10.2 | 16 | 21 | 115.52 | 90.7 | 1,088.4 |
| IPE 550 | 550 | 210 | 11.1 | 17.2 | 24 | 134.42 | 106 | 1,272 |
| IPE 600 | 600 | 220 | 12 | 19 | 24 | 155.98 | 122 | 1,464 |
What are the section properties of IPE beams?
Here y is the strong axis and z the weak axis. Some tables call these x and y, so check the notation before you read a value. Values are from Eurocode Applied and include the root fillets.
| Size | Iy (cm⁴) | Wel,y (cm³) | Wpl,y (cm³) | iy (cm) | Iz (cm⁴) | Wel,z (cm³) | iz (cm) |
|---|---|---|---|---|---|---|---|
| IPE 80 | 80.1 | 20.0 | 23.2 | 3.24 | 8.5 | 3.7 | 1.05 |
| IPE 100 | 171.0 | 34.2 | 39.4 | 4.07 | 15.9 | 5.8 | 1.24 |
| IPE 120 | 317.8 | 53.0 | 60.7 | 4.90 | 27.7 | 8.6 | 1.45 |
| IPE 140 | 541.2 | 77.3 | 88.3 | 5.74 | 44.9 | 12.3 | 1.65 |
| IPE 160 | 869.3 | 108.7 | 123.9 | 6.58 | 68.3 | 16.7 | 1.84 |
| IPE 180 | 1,317 | 146.3 | 166.4 | 7.42 | 100.9 | 22.2 | 2.05 |
| IPE 200 | 1,943 | 194.3 | 220.6 | 8.26 | 142.4 | 28.5 | 2.24 |
| IPE 220 | 2,772 | 252.0 | 285.4 | 9.11 | 204.9 | 37.3 | 2.48 |
| IPE 240 | 3,892 | 324.3 | 366.6 | 9.97 | 283.6 | 47.3 | 2.69 |
| IPE 270 | 5,790 | 428.9 | 484.0 | 11.23 | 419.9 | 62.2 | 3.02 |
| IPE 300 | 8,356 | 557.1 | 628.4 | 12.46 | 603.8 | 80.5 | 3.35 |
| IPE 330 | 11,770 | 713.1 | 804.3 | 13.71 | 788.1 | 98.5 | 3.55 |
| IPE 360 | 16,270 | 903.6 | 1,019 | 14.95 | 1,043 | 122.8 | 3.79 |
| IPE 400 | 23,130 | 1,156 | 1,307 | 16.55 | 1,318 | 146.4 | 3.95 |
| IPE 450 | 33,740 | 1,500 | 1,702 | 18.48 | 1,676 | 176.4 | 4.12 |
| IPE 500 | 48,200 | 1,928 | 2,194 | 20.43 | 2,142 | 214.2 | 4.31 |
| IPE 550 | 67,120 | 2,441 | 2,787 | 22.35 | 2,668 | 254.1 | 4.45 |
| IPE 600 | 92,080 | 3,069 | 3,512 | 24.30 | 3,387 | 307.9 | 4.66 |
- I (second moment of area): bending stiffness, used to calculate deflection.
- Wel (elastic section modulus): the second moment of area divided by the distance to the outermost fibre.
- Wpl (plastic section modulus): relates to the fully plastic bending moment of the section.
- i (radius of gyration): used to check slenderness and buckling of compression members.
Comparing sizes with the table: a worked example
Bending stress equals bending moment divided by section modulus. For a beam carrying a moment of 50 kN·m (50 × 10⁶ N·mm), with the section modulus converted to mm³:
- IPE 240: (50 × 10⁶) ÷ (324.3 × 10³) ≈ 154 N/mm²
- IPE 200: (50 × 10⁶) ÷ (194.3 × 10³) ≈ 257 N/mm²
Eurocode Applied's material table gives S235 a yield strength of 235 N/mm² up to 40 mm thick, so IPE 200 exceeds it in this example. This calculation only explains the table and is not a design; loads, safety factors, lateral buckling and deflection are for the structural engineer to check.
The same rows show something else. IPE 240 is about 37% heavier than IPE 200, but its second moment of area about the strong axis is twice as large. The second moment of area of IPE 240 about the weak axis is only about one-fourteenth of its strong-axis value, which is why beams are normally installed to bend about the strong axis, with lateral buckling restrained.
How do you work out beam weight from the area?
The same material table gives the density of steel as about 7,850 kg/m³, which gives a simple rule:
Mass per metre (kg) ≈ area (cm²) × 0.785
For IPE 240: 39.12 × 0.785 ≈ 30.7 kg/m, matching the catalog. For IPE 550 and IPE 600 the rule gives 105.5 and 122.4, while the catalog records the rounded values 106 and 122.
How section tables differ between sources
Figures do not always match between sources. The Eurocode Applied table and our catalog take r as 18 mm for IPE 330, with Iy about 11,770 cm⁴; the British Steel datasheet lists r as 20 mm and Iy as 11,908 cm⁴ for the same size. The difference does not appear in the small sizes.
For purchasing, three points are enough:
- Take size, grade and length from the drawings, not from a trade name.
- If the calculations used a particular table, keep to that table.
- Do not substitute another section such as IPN without the engineer's approval; see IPE vs IPN beams.
Summary
An IPE section table puts each size's dimensions, weight and bending properties side by side: section modulus to compare stress, second moment of area for deflection, area for weight. All sizes are listed in our beam category, and you can send your project list through the contact page for a quotation.
Frequently asked questions
What does an IPE section table show?
For each IPE size it lists the cross-section dimensions, mass per metre and geometric properties such as area, second moment of area and section modulus. It is used to compare sizes and in structural calculations.
What is the section modulus of IPE 200?
Per the Eurocode Applied table, the elastic section modulus of IPE 200 about the strong axis is about 194.3 cm³, and the plastic section modulus is about 220.6 cm³.
What is the cross-section area of IPE 180?
Per the Eurocode Applied table, IPE 180 has a cross-section area of about 23.95 cm². Multiplying it by 0.785 gives its mass per metre, about 18.8 kg.
Why do section tables differ slightly between sources?
Section properties depend on the root radius between flange and web, and some mills publish a different value. For final design, use the table adopted in the project calculations and the data supplied with the delivered material.
Sources
- Ahan Assa public product catalog: IPE dimensions, nominal weight, grade and standard — Ahan Assa
- IPE, HEA, HEB and HEM design properties (EN 1993, S235 table) — Eurocode Applied
- European sections: IPE sections, dimensions and properties — British Steel
- Table of material properties for structural steel S235, S275, S355, S420 — Eurocode Applied
By Ahan Assa Editorial Team
Related articles

Standards & specifications
Mill Test Certificate (MTC): How to Read and Check It
What a mill test certificate (MTC) shows, how EN 10204 types 2.1, 2.2, 3.1 and 3.2 differ, and what to check on delivery, including the heat number.
4 min read

Standards & specifications
UPN vs UPE Channel: Differences, Sizes and Weight
UPN vs UPE channels: tapered or parallel flanges, dimensions and weight per metre at equal depth, taper washers for bolting, and where each is used.
4 min read

Standards & specifications
Pipe Schedule Explained: SCH40 OD, Wall and Weight
What a pipe schedule number means, why nominal size is not the outside diameter, SCH40 vs SCH80 walls, and our SCH40 seamless pipe table with kg per metre.
4 min read